Search for heat leaks. Thermal imaging inspection thermal imager + air door.

Search for heat leaks. Thermal imaging inspection thermal imager + air door.

№156675
Created: May 16 2022
Search for heat leaks. Thermal imaging inspection thermal imager + air door. Almaty - photo 1
Search for heat leaks. Thermal imaging inspection thermal imager + air door. Almaty - photo 2
Search for heat leaks. Thermal imaging inspection thermal imager + air door. Almaty - photo 3
Search for heat leaks. Thermal imaging inspection thermal imager + air door. Almaty - photo 4
Search for heat leaks. Thermal imaging inspection thermal imager + air door. Almaty - photo 5
Search for heat leaks. Thermal imaging inspection thermal imager + air door. Almaty - photo 6
Search for heat leaks. Thermal imaging inspection thermal imager + air door. Almaty - photo 7
Search for heat leaks. Thermal imaging inspection thermal imager + air door. Almaty - photo 8
Address: Almaty, Kazakhstan
It is known that up to 50% of heat loss in buildings is due to defects in building envelopes, which are associated with the leakage of warm air. When diagnosing only with THERMAL IMAGE, most of these defects are not visible. The Blower Door comes to the rescue. This device got its name due to the use of a special fan inserted into the front door through a flexible membrane. Two components of this equipment made its use not only convenient, but also mandatory. The main thing is that the technology of such an examination is based on a forced decrease or increase pressure inside the building, relative to natural conditions outside. As a result, air flows are significantly increased, penetrating through all the hidden defects of the building. In addition, there is no need to conduct an examination with a thermal imager at a relatively large, at 15C? -20C?, difference between outside and inside air. A temperature difference of 3-5 C is enough, which allows you to conduct an examination at almost any time of the year, and not only during the heating period. Ideally, such a joint check (air door + thermal imager) should be carried out before the start of finishing work inside the building. The result of the survey will be the identification of all construction defects that can be corrected in time, thereby saving on repairs in the future. Possibilities of application: detection of areas by infiltration using a thermal imager, a smoke generator and a thermomanometer. calculation of real heat losses associated with air infiltration, inspection of premises for compliance with building codes in terms of air exchange rate and air permeability. checking the quality of construction work in the field of thermal insulation and hydro-vapor barrier. identification of cold bridges and dew points. checking the tightness of rooms for special purposes. analysis and evaluation of design values for ventilation, air conditioning and heating. Carrying out the test for air permeability with an air door, together with a simultaneous examination with a thermal imager, allows you to obtain the most reliable data on the state of building envelopes, the presence of defects and the possibility of their correction, as well as conduct a thermal imaging examination ALL YEAR ROUND. AFTER THE SURVEY YOU WILL RECEIVE A REPORT IN PDF FORMAT With an indication of all problem areas and Recommendations for their elimination. You can get detailed advice by calling What's App 87011740089 Anatoly. And also on our Instagram page: blower_doorkz. Thermal imaging surveys are carried out only with professional devices: 1. Flir T 300 thermal imager. 2. Moisture meter with built-in Flir mr160 thermal imaging module. 3. Minneapolis blower door modell 4.1
№156675
Created: May 16 2022
noname
Was online november 30 2023 11:27
Log In or Sign In to leave comment.
noname
Was online november 30 2023 11:27
Do you want more people to see this listing?
Promote listing